Content
- 1 What Are B1 and B2 Low-Smoke Halogen-Free Insulation Materials?
- 2 Product Composition and Functional Design
- 3 Key Performance Profile
- 4 Fire Classification and Application Significance
- 5 Advantages Compared with Conventional and Competing Material Approaches
- 6 Advanced Manufacturing Process
- 7 Manufacturing Strengths of Jiangsu Duoshang New Materials Technology Co., Ltd.
- 8 Processing Recommendations for Cable Manufacturers
- 9 Quality, Safety, and Sustainability Considerations
- 10 How to Select the Correct Grade
- 11 Frequently Asked Questions
- 11.1 What is the main use of these B1 and B2 materials?
- 11.2 Are these materials suitable for all cable applications?
- 11.3 What is the difference between the B1 and B2 versions?
- 11.4 Do the materials contain halogens?
- 11.5 How do the materials reduce smoke?
- 11.6 Can the material be processed on standard cable-extrusion equipment?
- 11.7 What mechanical properties are available?
- 11.8 How does the compound perform at elevated temperature?
- 11.9 Is the material suitable for low-temperature environments?
- 11.10 Can customized grades be developed?
- 11.11 What information should a customer provide when requesting a recommendation?
- 12 Conclusion
- 13 References
- 14 Product: B1 and B2 low smoke halogen-free insulation materials

Modern cable systems are expected to provide electrical reliability, mechanical durability, fire safety, and environmental performance at the same time. These requirements are especially demanding in buildings, transportation systems, data centers, power installations, renewable-energy projects, and communication networks where cables may be installed in enclosed or densely occupied spaces. In such applications, the insulation and sheath compound must do more than protect the conductor. It must also limit flame spread, reduce smoke generation, avoid corrosive halogen gases, maintain stable electrical properties, and support reliable high-speed cable manufacturing.
B1 and B2 low-smoke halogen-free insulation materials are designed to address these requirements. The product described in this article is a polyolefin-based compound intended mainly for the insulation layer of BYJ wire and other flame-retardant cable constructions. It combines polyolefin resin with a high-efficiency flame-retardant system, flame-retardant synergists, carbonization agents, antioxidants, and processing auxiliaries. After compounding and twin-screw extrusion, the formulation is converted into uniform pellets suitable for cable extrusion.
The material has been developed to meet demanding requirements for flame retardancy, low smoke toxicity, low corrosiveness, electrical insulation, thermal stability, and resistance to dripping. Its stated performance corresponds to the B1 and B2 classification requirements of GB 31247-2014 and the B1ca, B2ca, and Cca classification requirements of EN 13501-6. Depending on the selected grade and cable construction, the material can support projects that require a carefully balanced combination of fire performance and processing efficiency.
Beyond the formulation itself, product value depends on manufacturing consistency, technical support, research capability, quality control, and supply stability. Jiangsu Duoshang New Materials Technology Co., Ltd. combines polymer research, production-line experience, application testing, and customized compound development to serve cable manufacturers in power, communications, rail transit, marine, photovoltaic, new-energy, locomotive, and other sectors.

B1 and B2 low smoke halogen-free insulation materials
What Are B1 and B2 Low-Smoke Halogen-Free Insulation Materials?
B1 and B2 low-smoke halogen-free insulation materials are specialized cable compounds formulated to provide enhanced fire behavior without relying on conventional halogen-containing flame-retardant systems. The term “low-smoke halogen-free,” often abbreviated as LSZH, refers to a material design approach in which the compound is intended to produce limited smoke and very low levels of halogen acid gases during combustion.
In a conventional halogen-containing cable material, chlorine- or bromine-based components may contribute to flame resistance. However, when such materials burn, they can generate dense smoke and corrosive gases. These emissions can reduce visibility, hinder evacuation, damage electronic equipment, and create additional hazards for emergency personnel. LSZH compounds use alternative flame-retardant technologies, frequently based on mineral flame retardants, synergistic additives, char-forming components, and carefully selected polymer systems.
The material discussed here uses polyolefin resin as the main polymer matrix. Polyolefins are widely used in cable applications because they offer a useful combination of insulation performance, flexibility, processability, moisture resistance, and chemical stability. The challenge is that untreated polyolefin is combustible. The formulation therefore incorporates a coordinated flame-retardant package designed to improve ignition resistance, reduce flame propagation, encourage protective carbonization, and limit dripping.
B1 and B2 do not represent merely different product names. They indicate different levels within a fire-classification system. The appropriate grade depends on the cable design, installation environment, required reaction-to-fire classification, conductor size, extrusion conditions, and final certification program. The DS-ZWG-105-B1, DS-WDZF-105-B1, and DS-GW-105-B1 grades are presented as B1-oriented materials, while DS-ZWG-105-B2, DS-WDZF-105-B2, and DS-GW-105-B2 are presented as B2-oriented materials.
Each grade can be evaluated using a combination of physical, thermal, electrical, and combustion-related indicators. These include tensile strength, elongation at break, oxygen index, thermal aging behavior, hot elongation, smoke density, volume resistivity, dielectric strength, low-temperature brittleness, pH value, halide content, and conductivity. Looking at the complete property profile is more useful than judging the compound by a single flame-retardancy value.
Product Composition and Functional Design
Polyolefin Resin Matrix
The polyolefin resin forms the continuous phase of the compound and provides the foundation for mechanical and electrical performance. A suitable resin matrix allows the compound to be extruded around a conductor with a stable surface, consistent diameter, and reliable adhesion or interfacial contact where required by the cable structure. It also provides the flexibility needed during cable installation and service.
Polyolefin-based insulation compounds are attractive because they can provide high volume resistivity and strong dielectric performance. In the typical data supplied for this product family, volume resistivity at 20°C reaches approximately 2.3 × 1014 to 5.0 × 1014 Ω·cm, while dielectric strength is listed at approximately 28 MV/m for all reported grades. These values demonstrate the material’s suitability for insulation applications when the finished cable is correctly designed and processed.
High-Efficiency Flame-Retardant System
The flame-retardant system is responsible for improving the compound’s reaction to fire. A well-designed system can act through several mechanisms: absorbing heat, releasing nonflammable gases, diluting combustible decomposition products, promoting a protective residue, and interrupting the combustion cycle. The goal is not simply to increase the amount of additive. Excessive loading may reduce tensile strength, impair elongation, lower processability, increase density, or affect electrical properties.
The product’s typical oxygen index values range from 38% to 40%, compared with a stated standard requirement of at least 28%. A higher oxygen index generally indicates that a material requires a more oxygen-rich environment to sustain combustion. This result is one indicator of improved flame resistance, although final cable classification must still be verified through the appropriate finished-product tests.
Flame-Retardant Synergists and Carbonization Agents
Synergists are used to improve the performance of the primary flame-retardant components. In practical terms, a synergistic formulation may achieve better fire performance with a more balanced additive level than a formulation relying on one flame retardant alone. Carbonization agents support the development of a protective char or carbonized layer during combustion. This layer can slow heat transfer, reduce the release of combustible gases, and help protect the underlying polymer.
For cable insulation, the flame-retardant system must also be compatible with extrusion. Additives should be dispersed evenly throughout the polymer matrix, and the compound should remain sufficiently stable during melting, conveying, and cooling. Poor dispersion can create weak points, surface defects, inconsistent flame behavior, or variation in electrical properties. This is why the mixing sequence, temperature profile, screw configuration, residence time, and pelletizing conditions are important parts of the manufacturing process.
Antioxidants and Processing Auxiliaries
Antioxidants help protect the polymer during high-temperature processing and long-term service. They can reduce unwanted oxidation reactions that would otherwise cause discoloration, molecular-weight loss, embrittlement, or a decline in mechanical performance. Processing auxiliaries support melt flow, dispersion, surface quality, and extrusion stability.
The additive package must be carefully balanced. An additive that improves one property may influence another. For example, increasing mineral loading may improve flame resistance but can affect flexibility and elongation. A processing aid may improve surface appearance but must remain compatible with electrical requirements. A stable product therefore depends on formulation engineering rather than on one isolated ingredient.
Key Performance Profile
The supplied typical data show that the B1 and B2 material series have been designed as balanced insulation compounds rather than single-purpose flame-retardant products. Their values indicate a combination of mechanical strength, high elongation, thermal stability, fire performance, smoke control, and electrical insulation.
| Property | Unit | Standard or Requirement | Typical B1 Range | Typical B2 Range |
|---|---|---|---|---|
| Specific gravity | g/cm³ | Reference value | 1.58–1.59 | 1.57–1.58 |
| Tensile strength | MPa | ≥10.0 | 10.0–11.5 | 10.0–11.5 |
| Elongation at break | % | ≥150 | 170–175 | 175–180 |
| Oxygen index | % | ≥28 | 40 | 38 |
| Hot elongation at 200°C | % | ≤100 | 35–50 | 35–50 |
| Flaming smoke density | — | ≤100 | 45–55 | 45–65 |
| Flameless smoke density | — | ≤350 | 255–260 | 255–275 |
| Volume resistivity at 20°C | Ω·cm | 1.0 × 1014 | 2.5 × 1014–5.0 × 1014 | 2.3 × 1014–4.8 × 1014 |
| Dielectric strength | MV/m | ≥20 | 28 | 28 |
| Low-temperature brittleness | °C | −25 | Pass | Pass |
| pH value | — | ≥4.3 | 5.1–5.2 | 5.2 |
| HCl and HBr content | % | ≤0.5 | <0.5 | <0.5 |
| Conductivity | μS/mm | ≤10 | 0.51–0.53 | 0.51–0.52 |
Mechanical Strength and Elongation
Tensile strength is reported at 10.0 MPa or higher for the listed grades, with typical values from 10.0 to 11.5 MPa. This level provides a practical mechanical foundation for insulation that must withstand extrusion handling, cable winding, installation, and service-related movement.
Elongation at break is reported from 170% to 180%, exceeding the stated minimum requirement of 150%. High elongation is valuable because cable insulation may be exposed to bending, pulling, vibration, thermal expansion, and installation stress. A material with adequate tensile strength but insufficient elongation may crack or tear during processing. The combination of strength and elongation is therefore more meaningful than either measurement by itself.
Compared with heavily filled compounds that may become stiff or brittle, this material profile suggests a more balanced approach to flame-retardant loading. The formulation retains substantial ductility while maintaining enhanced fire performance. This balance can help cable manufacturers reduce the risk of insulation damage during production and installation.
Thermal Aging Stability
The material is evaluated after air thermal aging at 135°C for 168 hours. The typical change in tensile strength is approximately +15% to +18%, while the change in elongation is approximately −13% to −20%. Both results remain within the stated ±25% requirement.
Thermal aging data are important for cables used near heat-producing equipment, in power distribution systems, in transportation vehicles, or in installations where the cable operates continuously at elevated temperature. A controlled change in mechanical properties after aging indicates that the polymer and additive system can retain a useful degree of integrity under accelerated thermal exposure.
Thermal aging performance also supports process reliability. If the compound is susceptible to rapid thermal degradation, the extrusion process may generate unstable melt behavior, discoloration, surface roughness, or premature mechanical deterioration. Antioxidant selection and processing control help reduce these risks.
Hot Elongation and Permanent Deformation
Hot elongation is reported at 200°C under a 0.2 MPa load for 15 minutes. The listed elongation under load ranges from 35% to 50%, well below the stated maximum of 100%. Permanent deformation after cooling is reported between −5% and 0%, compared with a maximum requirement of 25%.
These results indicate good resistance to excessive deformation when the insulation is exposed to elevated temperature and mechanical stress. This characteristic is especially useful during cable processing and in service environments where heat may soften the polymer. Low permanent deformation helps the insulation retain its original dimensions after the load is removed and the material cools.
Smoke Density and Low-Corrosiveness Performance
Smoke control is a central advantage of LSZH cable materials. The reported flaming smoke density values range from 45 to 65, against a stated limit of 100. Flameless smoke density values range from 255 to 275, against a stated limit of 350. These results indicate that the compound is formulated to limit smoke generation under both flaming and flameless conditions.
Lower smoke density can improve visibility during evacuation and may reduce the difficulty of locating fire sources or performing emergency operations. It can also help limit contamination of sensitive equipment. The actual safety benefit depends on the complete cable design, installation conditions, ventilation, and the amount of cable present, but the compound is designed to contribute to a lower-smoke system.
The HCl and HBr content is listed as less than 0.5% for all typical grades. The pH value ranges from 5.1 to 5.2, above the stated minimum of 4.3, while conductivity is approximately 0.51 to 0.53 μS/mm, far below the stated maximum of 10 μS/mm. These indicators support the low-corrosiveness and low-acidity objectives of halogen-free cable materials.
In comparison with conventional halogen-containing insulation, a properly formulated LSZH compound can help reduce the production of acidic and corrosive gases during combustion. This is particularly relevant in data centers, control rooms, hospitals, public buildings, tunnels, rail vehicles, ships, and other areas containing electronic systems or large numbers of occupants.
Fire Classification and Application Significance
The product is described as meeting the B1 and B2 level classification combustion standards in GB 31247-2014. It is also described as meeting the B1ca, B2ca, and Cca level classification combustion standards in EN 13501-6. These classifications are associated with reaction-to-fire performance for cable products and are used to distinguish different levels of fire behavior.
Classification should always be confirmed for the complete finished cable rather than assumed solely from the raw compound. Cable diameter, conductor material, insulation thickness, filler, shielding, jacket construction, installation configuration, and test preparation can all influence the final result. The compound provides a carefully engineered foundation, but the cable manufacturer remains responsible for validating the final cable assembly and obtaining project-specific approvals.
B1-oriented compounds may be considered for applications with particularly demanding fire-performance objectives. B2-oriented compounds may be selected where a different balance of flame retardancy, processing behavior, cost, or application requirements is appropriate. The selection should be made with reference to the applicable national or regional standard, project specification, cable category, and testing laboratory requirements.
BYJ Wire Insulation
The primary stated application is the insulation layer of BYJ wire. For this use, the compound must provide adequate electrical insulation, mechanical flexibility, thermal stability, and resistance to flame propagation. It must also be processed into a smooth, concentric layer around the conductor without voids, excessive surface roughness, or dimensional instability.
The reported dielectric strength of 28 MV/m and high volume resistivity support the electrical requirements of an insulation layer. The combination of tensile strength and elongation supports manufacturing and installation durability. The hot elongation results indicate that the insulation can resist excessive deformation during elevated-temperature exposure when the cable construction and operating conditions are properly matched.
Power and Energy Cables
Power cables installed in buildings, substations, industrial facilities, photovoltaic systems, and new-energy projects may need to comply with strict fire-safety requirements. LSZH insulation compounds can help reduce smoke and corrosive emissions if a fire occurs. This is valuable in enclosed electrical rooms, energy-storage facilities, utility tunnels, and distributed-energy installations.
For photovoltaic and renewable-energy cable applications, material selection may also involve resistance to weather, ultraviolet exposure, moisture, temperature cycling, and mechanical movement. The B1 and B2 compound may be evaluated as part of a broader cable system in which the insulation material is paired with a suitable sheath and other protective layers.
Communication and Optical Cable Systems
Communication cables and optical cables are often installed in high-density bundles, risers, equipment rooms, and data centers. In these environments, smoke and corrosive emissions may threaten both people and valuable electronic equipment. LSZH compounds can support safer cable designs by reducing smoke density and halogen-acid emissions.
The high electrical resistivity and dielectric strength reported for the compound are also relevant to communication cable insulation. However, high-frequency performance depends on the entire cable geometry, dielectric constant, dissipation factor, conductor arrangement, shielding, and manufacturing precision. The compound should therefore be validated against the electrical requirements of the specific communication or optical cable design.
Rail, Locomotive, Marine, and Transportation Cables
Transportation systems create specialized fire-safety challenges. Rail vehicles, locomotives, ships, and mass-transit infrastructure may contain many cables in confined spaces. Evacuation routes can be limited, and smoke can quickly affect visibility. Low-smoke, halogen-free construction is therefore frequently considered for these applications.
The material’s low-temperature brittleness test is reported as passing at −25°C. This is useful for applications exposed to cool environments, outdoor storage, transport, or temperature changes. Additional testing may be required for specific rail, marine, or vehicle standards, including oil resistance, fuel resistance, ozone resistance, vertical flame tests, toxicity, vibration, and environmental aging.
Advantages Compared with Conventional and Competing Material Approaches
Lower Smoke and Reduced Corrosive Emissions
One of the clearest advantages of this material family is its emphasis on low smoke and halogen-free combustion behavior. Conventional PVC and other halogen-containing systems can offer good flame resistance, but their combustion products may include dense smoke and acidic gases. These emissions can harm people, corrode metals, contaminate equipment, and complicate post-fire recovery.
The reported smoke-density values are well below the stated limits, while HCl and HBr content is below 0.5%, pH is above 5.1, and conductivity remains close to 0.5 μS/mm. These results show that the compound is designed to address smoke and corrosivity as integrated performance requirements rather than treating flame resistance as the only objective.
Balanced Flame Retardancy and Mechanical Performance
Some highly filled flame-retardant compounds achieve strong fire performance at the expense of elongation, flexibility, surface quality, or extrusion speed. The typical values for this product family show elongation at break of 170% to 180% and tensile strength up to 11.5 MPa. The oxygen index reaches 38% to 40%, and hot elongation remains substantially below the stated limit.
This balance may provide an advantage over formulations that become excessively rigid or difficult to process. Cable manufacturers can benefit from a compound that maintains reasonable mechanical behavior while meeting enhanced fire-performance objectives. Final results will depend on the extrusion equipment, die design, conductor preparation, cooling conditions, and cable geometry, but the raw material profile is intended to support a practical production window.
Stable Electrical Insulation
Adding flame retardants to a polymer can negatively affect electrical insulation if moisture absorption, ionic impurities, filler agglomeration, or additive migration is not controlled. The reported volume resistivity and dielectric strength indicate that the formulation has been engineered to preserve insulation performance.
Volume resistivity values of up to 5.0 × 1014 Ω·cm and dielectric strength of approximately 28 MV/m provide a strong electrical foundation. The low conductivity values reported in combustion-related testing also support the low-corrosiveness objective. Cable designers should still conduct finished-cable electrical tests under the intended voltage, temperature, humidity, and aging conditions.
Thermal and Dimensional Stability
The 135°C aging results, 200°C hot-elongation results, and low permanent deformation values indicate that the material can retain dimensional and mechanical stability under accelerated thermal conditions. Compared with less stable flame-retardant formulations, this can reduce the likelihood of insulation shrinkage, excessive deformation, cracking, or loss of mechanical integrity.
Thermal stability is also important for production efficiency. A compound that has a stable melt and predictable cooling behavior can help reduce line interruptions, scrap, die deposits, surface defects, and variation in insulation thickness. Consistency at the pellet level is therefore directly connected to the cable manufacturer’s productivity.
Multiple Grade Options
The availability of three B1 grades and three B2 grades provides cable manufacturers with options for different processing requirements and performance targets. The model families include DS-ZWG-105, DS-WDZF-105, and DS-GW-105 variants, each offered in B1 and B2 versions.
Multiple grades make it possible to consider differences in conductor size, insulation thickness, extrusion line configuration, flexibility requirements, smoke performance, and end-use standards. Rather than forcing every application into one universal formulation, a grade family allows technical teams to select a closer match and request application-specific recommendations when necessary.
Advanced Manufacturing Process
Performance consistency in cable compounds depends on the entire manufacturing chain. A technically sophisticated formula can underperform if raw materials are not controlled, additives are not dispersed, moisture is not managed, or pelletizing is inconsistent. The manufacturing process used for this product is based on compounding and granulation through twin-screw extrusion.
Raw-Material Selection and Incoming Control
The process begins with the selection of polyolefin resin, flame retardants, synergists, carbonization agents, antioxidants, and auxiliary additives. Each component affects the final material. Resin melt behavior influences extrusion stability and mechanical properties. Flame-retardant particle size and surface treatment affect dispersion. Antioxidant quality affects thermal stability. Processing auxiliaries influence torque, pressure, surface appearance, and throughput.
Incoming inspection may include identity confirmation, moisture measurement, particle-size evaluation, density checks, melt-flow assessment, and appearance inspection. Consistent raw materials reduce batch-to-batch variation and help maintain stable processing conditions. In a professional compounding operation, supplier qualification and lot traceability are important parts of quality management.
Precision Weighing and Premixing
Accurate dosing is essential for a multi-component LSZH formulation. Small deviations in flame-retardant concentration, synergist ratio, antioxidant level, or processing-aid content can affect flame performance, mechanical properties, and electrical behavior. Automated or controlled weighing systems can improve repeatability and reduce operator-dependent variation.
Premixing helps distribute additives before they enter the extruder. The objective is to avoid local concentrations and to provide a more uniform feed to the compounding zone. Moisture control is also important because some flame-retardant fillers may absorb moisture, which can create bubbles, surface defects, hydrolytic reactions, or unstable electrical properties during extrusion.
Twin-Screw Compounding
Twin-screw extrusion is well suited to formulations containing polymer resin and a relatively high level of functional additives. The intermeshing screws provide conveying, melting, distributive mixing, and dispersive mixing. Different screw elements can be arranged to create controlled melting and mixing zones while limiting excessive shear or residence time.
During compounding, the polymer is melted and the additive package is incorporated into the melt. The temperature profile must be high enough to achieve complete melting and good dispersion but low enough to minimize polymer degradation. Screw speed, feed rate, barrel temperature, vacuum venting, melt pressure, and torque are monitored to keep the process within a stable window.
Uniform dispersion is particularly important for flame-retardant compounds. Agglomerated particles can act as stress concentrators, reduce elongation, produce rough surfaces, or create inconsistent combustion behavior. Proper twin-screw design and process control help create a more homogeneous compound in which the flame-retardant system is distributed throughout the polyolefin matrix.
Degassing and Melt Filtration
Moisture and volatile components may be released during compounding. Vacuum degassing can help remove these substances before pelletizing. Effective venting reduces the risk of bubbles, voids, surface pitting, and unstable extrusion pressure.
Melt filtration may be used to remove foreign particles or unmixed agglomerates. Filtration requirements depend on the formulation, production rate, and final cable application. Maintaining clean melt flow supports a smooth pellet surface and helps protect downstream cable-extrusion equipment.
Pelletizing and Cooling
After compounding, the homogeneous melt is formed into pellets. Pellet dimensions, shape, moisture level, and flow characteristics affect feeding performance on the cable-extrusion line. Uniform pellets help maintain a consistent feed rate and reduce surging.
Cooling conditions must be controlled to prevent excessive moisture pickup, deformation, or incomplete solidification. Finished pellets are commonly screened to remove fines and oversized particles before packaging. Proper packaging protects the material during storage and transport and helps preserve its processing properties.
Batch Testing and Traceability
Quality assurance should connect every finished batch to its raw materials, process conditions, test results, packaging, and shipment record. Typical testing may include density, tensile strength, elongation, oxygen index, thermal aging, hot elongation, smoke density, volume resistivity, dielectric strength, low-temperature brittleness, pH, halide content, and conductivity.
Testing is most valuable when supported by clear sampling procedures, calibrated equipment, trained technicians, and documented acceptance criteria. Statistical review of production data can identify gradual process drift before it becomes a customer complaint. This approach supports both product reliability and continuous improvement.
Manufacturing Strengths of Jiangsu Duoshang New Materials Technology Co., Ltd.
Jiangsu Duoshang New Materials Technology Co., Ltd. specializes in the research, development, production, and sales of polyolefin cable compounds. Its business is focused on polymer cable compounds and biodegradable materials, with product applications extending across power, communications, locomotives, photovoltaic systems, new-energy generation, rail transit, marine cables, and other industries.
The company operates a research and development center of more than 3,000 square meters. The center is equipped with more than RMB 35 million worth of research equipment and supported by a professional R&D team of more than 30 members, including five doctors and several recipients of provincial and municipal talent awards. This research structure provides a foundation for formulation development, testing, application evaluation, and problem-solving.
Production is carried out across two bases covering more than 15,000 square meters, with more than ten production lines dedicated to polyolefin cable compounds. This production footprint supports a portfolio of eight major product categories and more than 50 varieties. The portfolio includes UV-crosslinked compounds, silane cross-linkable compounds, irradiation cross-linked materials, thermoplastic LSZH flame-retardant compounds, polyethylene sheath compounds, and other specialized cable materials.
Multiple production lines can support flexible scheduling, product specialization, and supply continuity. For cable manufacturers, supply capability is important because a material change can require qualification, extrusion trials, electrical testing, and customer approval. A stable supplier reduces the risk of interruptions during routine production or project delivery.
The company also emphasizes application-oriented technical support. This can include material selection, processing recommendations, testing assistance, technical documentation, and customized formulations. Such support is especially useful when a customer needs to balance fire classification, extrusion speed, flexibility, conductor compatibility, smoke performance, and cost.
Processing Recommendations for Cable Manufacturers
Before production, the compound should be stored in clean, dry conditions and protected from moisture, contamination, and prolonged exposure to heat or direct sunlight. Packaging should remain sealed until the material is ready for use. If moisture exposure is suspected, the manufacturer should consult the supplier regarding drying requirements and suitable conditions.
The extrusion temperature profile should be established through a controlled trial rather than copied without adjustment from another material. LSZH formulations can respond differently to screw speed, back pressure, die temperature, cooling-water temperature, and line speed. Excessive temperature may cause degradation or surface discoloration, while insufficient melting or mixing may cause roughness and poor dimensional stability.
Conductor cleanliness and preheating can influence insulation quality. Oil, dust, oxide, or other contamination on the conductor may affect adhesion, surface appearance, electrical performance, and long-term reliability. The die and tooling should be selected to provide uniform coating thickness and stable concentricity.
During the trial, manufacturers should monitor extrusion pressure, melt temperature, motor load, line speed, insulation diameter, eccentricity, surface appearance, spark-test performance, and pellet consumption. Finished-cable testing should include the electrical, mechanical, thermal, and flame-related tests required by the applicable standard.
Because the product family includes several B1 and B2 variants, the most appropriate grade should be chosen according to the customer’s cable design. A technical discussion with the material supplier can help identify the grade that provides the best balance between fire performance and production behavior.
Quality, Safety, and Sustainability Considerations
Low-smoke halogen-free cable materials can contribute to safer building and infrastructure design by reducing smoke and corrosive emissions during a fire. However, material selection is only one part of a complete fire-safety strategy. Cable routing, installation density, fire barriers, emergency planning, ventilation, and inspection also affect overall risk.
From a manufacturing perspective, halogen-free compounds require responsible handling of powders, fillers, pellets, and process dust. Appropriate ventilation, personal protective equipment, housekeeping, and equipment maintenance should be used in accordance with site procedures and applicable regulations.
The longer service life of a reliable cable can also support resource efficiency by reducing maintenance, replacement, and premature disposal. In addition, the company’s broader focus on polymer cable compounds and biodegradable materials indicates an interest in developing materials that address both performance and changing environmental expectations. Specific environmental claims, recycling pathways, and life-cycle benefits should be evaluated for each formulation and application.
How to Select the Correct Grade
Grade selection should begin with the required fire classification. Determine whether the finished cable must satisfy a B1, B2, B1ca, B2ca, Cca, or another classification. The applicable standard may be determined by the country, building code, infrastructure owner, certification body, or project specification.
The second consideration is the operating temperature and thermal-aging requirement. The designer should review continuous operating temperature, short-term overload conditions, ambient temperature, installation location, and heat generated by neighboring cables or equipment.
The third consideration is mechanical behavior. Cable flexibility, minimum bending radius, pulling force, vibration, installation method, and expected movement all influence the appropriate balance between tensile strength and elongation.
The fourth consideration is extrusion compatibility. The manufacturer should evaluate feeder capacity, screw geometry, die design, line speed, insulation thickness, cooling conditions, and required surface quality. A grade that performs well on one line may require process adjustment on another.
The fifth consideration is electrical performance. Volume resistivity, dielectric strength, insulation resistance, capacitance, signal integrity, and voltage rating should be assessed according to the cable design. Where the material is used in communication or optical cable systems, high-frequency and transmission-related properties should be tested on the finished construction.
Finally, project-specific requirements such as ultraviolet resistance, oil resistance, water resistance, ozone resistance, chemical exposure, low-temperature flexibility, smoke toxicity, and long-term aging should be reviewed. The supplier can then recommend a grade or develop a customized compound where standard products do not fully meet the application.
Frequently Asked Questions
What is the main use of these B1 and B2 materials?
The primary stated use is the insulation layer of BYJ wire. They may also be evaluated for other power, communication, transportation, photovoltaic, marine, and specialized cable constructions where low smoke, halogen-free combustion behavior, flame retardancy, and electrical insulation are required.
Are these materials suitable for all cable applications?
No single compound is automatically suitable for every cable. The correct grade depends on conductor type, cable structure, operating temperature, installation environment, required fire classification, extrusion equipment, and certification requirements. Finished-cable validation is necessary before commercial use.
What is the difference between the B1 and B2 versions?
B1 and B2 refer to different fire-performance levels within the applicable classification systems. The B1 grades generally show oxygen index values of about 40% in the supplied typical data, while the B2 grades show values of about 38%. The final selection should be based on the required finished-cable classification and project specification.
Do the materials contain halogens?
The product is described as low-smoke halogen-free. The supplied data list HCl and HBr content below 0.5% for the reported grades. Customers should request the applicable technical documentation and verify the exact formulation and test method for their compliance program.
How do the materials reduce smoke?
The formulation combines a polyolefin matrix with a coordinated flame-retardant system, synergists, and carbonization agents. These components are designed to control decomposition, promote protective residue, and limit smoke generation. Typical flaming smoke density is reported from 45 to 65, and flameless smoke density from 255 to 275.
Can the material be processed on standard cable-extrusion equipment?
The material is produced as thermoplastic pellets for cable extrusion, but the exact processing window depends on the equipment and cable design. Temperature, screw speed, feed rate, die configuration, cooling, and line speed should be optimized through a controlled production trial.
What mechanical properties are available?
Typical tensile strength is reported at 10.0 to 11.5 MPa, while elongation at break is approximately 170% to 180%. These values exceed the stated minimum requirements of 10.0 MPa tensile strength and 150% elongation.
How does the compound perform at elevated temperature?
After air aging at 135°C for 168 hours, the typical tensile-strength change is approximately +15% to +18%, and elongation change is approximately −13% to −20%. Hot elongation at 200°C under 0.2 MPa for 15 minutes is reported at 35% to 50%, with permanent deformation after cooling between −5% and 0%.
Is the material suitable for low-temperature environments?
The listed grades pass the low-temperature brittleness test at −25°C. Additional low-temperature flexibility testing may be needed if the cable will operate below this temperature or experience repeated cold bending.
Can customized grades be developed?
The company provides application-oriented R&D and customized material solutions. Customization may be considered for specific requirements involving flame classification, flexibility, extrusion behavior, electrical properties, thermal performance, weather resistance, or other application factors.
What information should a customer provide when requesting a recommendation?
Useful information includes the cable type, conductor material and size, insulation thickness, target fire classification, operating temperature, installation environment, extrusion equipment, line speed, required electrical properties, applicable standards, and estimated annual volume. Representative samples and processing feedback can further improve grade selection.
Conclusion
B1 and B2 low-smoke halogen-free insulation materials provide a balanced approach to cable safety and performance. The product family combines a polyolefin resin matrix with flame retardants, synergists, carbonization agents, antioxidants, and processing auxiliaries. Its typical data show strong oxygen-index performance, controlled smoke density, low HCl and HBr content, low conductivity, high volume resistivity, useful dielectric strength, reliable elongation, thermal-aging stability, and resistance to hot deformation.
These characteristics offer meaningful advantages over conventional cable compounds that may generate more smoke or corrosive gases during combustion, as well as over heavily filled alternatives that can sacrifice flexibility or processing efficiency. The availability of several B1 and B2 grades provides additional flexibility for cable manufacturers developing products for power, communications, rail, marine, photovoltaic, new-energy, locomotive, and building applications.
Product performance is supported by Jiangsu Duoshang New Materials Technology Co., Ltd.’s R&D resources, professional technical team, production bases, multiple polyolefin-compound production lines, and application-oriented service model. Twin-screw compounding, controlled additive dispersion, degassing, pelletizing, batch testing, and traceability contribute to stable material quality and production reliability.
For the best results, the compound should be selected and validated according to the complete cable design and applicable certification requirements. When formulation engineering, controlled manufacturing, appropriate extrusion conditions, and finished-cable testing are combined, B1 and B2 LSZH materials can help manufacturers produce safer, more reliable, and more technically competitive cable systems.
References
GB 31247-2014, Classification and Test Requirements for Burning Behavior of Cables and Optical Cables.
EN 13501-6, Classification of Construction Products and Building Elements Regarding Their Reaction to Fire—Classification Using Data from Reaction to Fire Tests on Power, Control and Communication Cables.
Technical data supplied for B1 and B2 low-smoke halogen-free insulation material grades, including DS-ZWG-105-B1, DS-WDZF-105-B1, DS-GW-105-B1, DS-ZWG-105-B2, DS-WDZF-105-B2, and DS-GW-105-B2.
General principles of polyolefin cable-compound formulation, twin-screw extrusion, flame-retardant additive dispersion, thermal aging, smoke-density evaluation, and electrical insulation testing.
Manufacturer information concerning polyolefin cable-compound research, production capacity, product categories, technical support, and application fields.

English
Français
Español
русский
عربى